8.3 Connecting the compressed air line
Applies only for ASA mounting and ceiling in-
stallation.
Cut the grey compressed air line to the correct
length.
EW versions:
Guide the air hose through the
housing
[11-1]
onto the hose connector
[11-3]
and close the screw clamp
[11-2]
.
EW/DW versions:
Slide the grey air hose onto
the hose connector at the maintenance unit in-
let
[7-3]
and close the screw clamp
[7-2]
.
Secure the compressed air line and the mains
power and control cable to the aluminium pipe
[12-2]
using the three gripper clamp supplied
[12-1]
.
Insert the end of the blue hose into the connec-
tion
[5-1]
and guide the hose through the open-
ing on the housing.
Once you have attached all the connections in-
side the EAA, mount the rear panel on the EAA.
Push the blue air hose onto the elbow piece
[2-
5]
on the maintenance unit.
8.4 Mounting the hose holder
The hose holder is used to store consumable mate-
rials and hoses. Attach the two hose holders to the
rear panel of the EAA (see Fig.
[13]
).
Secure the hose holder
[13-4]
by screwing an
Allen screw
[13-2]
with washer
[13-3]
into both
holes using the Allen key
[13-1]
supplied.
Secure the rear panel to the EAA using the
screws supplied.
9 Connecting the dust extractor
A mobile dust extractor or the stationary TURBO
extraction system can be used to extract dust.
9.1 Mobile dust extractor
CT mobile dust extractors, series CT 22, CT 33, CT
44, CT 55
Fit the assembly set (module EAA CT22/33/44/
55: 495756) for the control cable to the CT mo-
bile dust extractor (see assembly instructions).
CT mobile dust extractor series CT 26, CT 36, CT 48
Fit the assembly set (module EAA CT26/36:
496143) to the CT mobile dust extractor (already
fitted on CTM 36/48 LE and CTL 36/48 LE mod-
els).
Plug the control cable into the socket on the ex-
tractor.
SRM mobile extractor and other brands of ex-
tractor
Connecting the control cable is no longer possible.
If the dust extractor has an appliance socket with
automatic switch-on unit, the mains cable on the
EAA must be plugged into this appliance socket so
that the automatic switch-on unit on the dust ex-
tractor functions. However, note the maximum ca-
pacity of the appliance socket. Not all EAA func-
tions can be used. We therefore recommend using
a Festool mobile dust extractor.
Plug the extractor hose into the extractor open-
ing on the dust extractor.
We recommend using rotating adapter D50
DAS-AS to connect the extractor hose to the
dust extractor.
If the EAA is quite far away from the mobile dust
extractor, part of the extractor hose should be
replaced by a plastic pipe or a steel pipe de-
signed for extraction systems (diameter 50
mm). This reduces the air flow resistance in the
extraction line and improves the suction power
at the EAA.
9.2 Stationary extraction system TURBO
Plug the control cableinto the socket on the ex-
traction system.
Plug the extractor hose into the extractor open-
ing on the extraction system (D75).
10 Power supply
Power and compressed air is supplied through the
energy box.
10.1 Power
All EAA versions have three sockets. Socket
[1-3]
is
connected permanently to the power. The two sock-
ets AUTO 1
[1-9]
and AUTO 2
[1-5]
are live when the
selector switch
[1-4]
is set to the "
AUTO
" position.
If the switch is set to "0" or "MAN", the sockets are
disconnected from the power supply.