The LED (3.2) indicates the respective charg-
ing state of the charger.
LED yellow – steady:
charger is ready for use.
LED green – fl ashing:
battery pack being charged.
LED green – steady:
battery pack fully charged, conservation charge
on.
LED red – fl ashing:
general malfunction, e. g. full contact not being
made, short-circuit, battery pack faulty.
LED red – steady:
temperature of battery pack is outside permis-
sible limit.
It is essential that you read the in-
structions in the Chapter „Maintenance - Care“.
Bit storage well
You can insert several bits or bit extensions into
the bit magazine (4.1) with magnetic holder.
Maintenance and care
Pay attention to the following instruc-
tions. Otherwise there is a risk of damage to the
tool, charger or battery pack.
Repairs may only be performed by authorised
technicians. LC 45 charging device: Even after
disconnection from the mains, there is still a
high capacitor voltage on the power output
component on the inside of the device.
Keep the air vents of the electronic equipment
and the charger clean to guarantee the air cir-
culation for cooling.
No metal objects (metal chips) should enter the
charger at the contact points as well as through
the cooling slits into the equipment (danger of
short circuit).
Only use original Festool battery packs. Do not
use spent and recycled battery packs. The user
shall be liable for damages if Festool original
battery packs are not used.
Keep the connection contacts of electronic
equipment, charger and battery pack clean.
By keeping the battery pack in a ready for use
charger, the battery pack will be kept in a state
of readiness by fl oat charging conservation.
Do not keep discharged battery pack (maximum
one month) attached to charger whenever char-
ger is detached from the power supply (danger
of deep discharging).
A new battery pack or a battery pack not used
for a longer period of time reaches it full ca-
pacity after about 5 charging and discharging
cycles.
Battery packs should, before charging, be fully
discharged if possible. Continuous starting of
the charging process shortens the lifespan of
the batteries.
A considerably reduced time of operation per
charging shows that the battery pack is used
up an should be replaced by a new one.
NiCd battery packs that are not used for lon-
ger periods should be stored in a discharged
state.
Special instructions for NiMH battery
packs:
The output of NiMH battery packs drops notice-
ably at ambient temperatures below 0° C or
above 45° C.
Do not overload the tool (do not load the tool
excessively so that it comes to a standstill).
Even if NiMH battery packs are not used, re-
charge them approx. every 4 months so that
they retain their full capacity.
NiMH battery packs should be left for 60 min.
in the charger after every 10th fast charge to
compensate any differences in capacity be-
tween the cells.
Because NiMH battery packs discharge auto-
matically, store them preferably at ambient
temperatures of between 0° C and 25° C.
Recycling battery packs
Never throw spent battery packs into domes-
tic waste containers! Return spent or defective
battery packs to dealers, the Festool after-sales
service department or approved waste disposal
facilities. This ensures that they are correctly